  • 400KW Shangchai power sc25g610d2 diesel generator set

    Model of generator set: kc400gf
     
    Main power: 400KW
     
    Standby power: 440kw
     
    Size of generator set: 3500 * 1400 * 2300mm
     
    Diesel engine brand: Shangchai power
     
    Model of diesel engine: sc25g610d2
     
    Weight of generator set: 3600kg
     
    Type of generator set: open shelf

    Last:320kw Shangchai power sc15g500d2 diesel generator set
    Next:450KW Shangchai power sc25g690d2 diesel generator set

    product details

    Shanghai Diesel Engine Co.,Ltd.,formerly known as Shanghai Diesel Engine Factory(hereinafter referred to as Shangchai power),was founded in 1947.In 1993,it was restructured into a state-owned holding company that issued a and B shares at home and abroad.Now it belongs to SAIC Group.It is a large-scale national high-tech enterprise engaged in R&D and manufacturing of engines,spare parts and generator sets.It has a national recognized technology center and postdoctoral workers The quality management system of workstation,industry famous automatic production line and passenger car standard.
    In nearly 70 years of development,the company's products are all over the world.At present,the company has seven series of diesel and natural gas engines,including R,h,D,C,e,G and W,with power covering 50~1600kw.They are mainly used in construction machinery,trucks,buses,power generation equipment,ships,agricultural machinery and other fields.Based on the"five vertical and seven horizontal"highway network,the company has built a sales and service support system composed of 19 offices,7 distribution centers,more than 300 core service stations and more than 1000 service providers.
    The company adheres to the quality policy of"implementing famous brand strategy,cultivating quality culture,pursuing quality benefit and ensuring customer satisfaction",adheres to the environmental policy of"strengthening systematic planning,advocating environmental friendliness;fulfilling compliance obligations,comprehensively preventing pollution;promoting clean production,insisting on resource conservation;continuously improving,pursuing green development",and practices the environmental policy of"implementing international standards,insisting on sustainable development"The occupational health and safety policy of"people-oriented;abide by laws and regulations,standardize employee behavior;improve intrinsic safety,adhere to continuous improvement;create world brand,go to the international market".
    Shangchai company practices the core values of integrity,openness,integration,innovation and progress,and strives to become the most reliable and competitive world-famous power system supplier.
     

    Diesel generator set parameters

    Model

    KC550GF

    Prime power

    550KW

    Standby power

    600KW

    Rated Voltage

    230/400

    Rated Current

    990A

    Generator set Frequency

    50Hz

    Rated Speed

    1500rpm

    Power Factor

    0.8

    DimensionsL*W*H

    3600*1400*2300mm

    Gross Weight

    4500Kg

    Alternator parameters

    Model

    KC-550-4

    Class of insulation

    H

    %Steady state voltage regulation

    +/-0.5

    %Transient voltage regulation

    +20-15

    %Steady state frequency regulation

    ±0.5

    %Transient frequency adjustment

    +10-7

    Material

    100% copper

    Voltage control mode

    AVR

    Degree of protection

    IP23

    Excitation

    Brushless self excitation

    Diesel engine parameters

    Brand

    SDEC

    Model

    SC27G900D2

    Prime power

    602KW

    Standby power

    662KW

    Configuration

    12cylinder 4 stroke V

    Fuel Injection way

           Direct injection

    Air inlet way

    Turbocharger

    Displacement

    26.6L

    Starting Voltage

    24V

    Speed adjustment mode

    Electronic Speed governing

    Bore Stroke

    135*155

    Fuel Consumption

    205g/kw*h

    Noise

    115

    Cooling System Capacity

    48L

    Lube Oil Capacity

    65L


    Standard configuration:

    Zhongzhi intelligent controller
    Battery automatic float charger
    Industrial water cooled diesel engine
    Single bearing drip proof generator,IP23 protection,insulation grade H
    40℃ambient temperature radiator,double layer heat dissipation
    Electric start
    Standard air filter
    Outlet switch
    Steel base with shock pad
    Muffler
    Battery
    Air switch cabinet(manual)

    Optional configuration:ATS automatic load conversion screen

    Rainproof generator set
    Silent generator set
    Container generator set
    High voltage generator set
    Parallel unit control panel
    Unit control panel with"three remote"function
    Mobile trailer unit(container trailer)
    Truck mobile power station
    Oil,diesel,water jacket,anti condensation heater
    Split daily fuel tank and integrated base fuel tank

    Maintenance instructions for diesel generator set

    1.Check before starting up every day.
    2.Engine crankcase oil consumption.
    3.Cooling liquid level:whether the radiator and intercooler core are blocked.
    4.Check whether the air filter is blocked.
    5.Check every 50 hours.
    6.Battery and liquid level:eliminate water leakage,fuel leakage and oil leakage.
    7.Every 250-300 hours:change the engine oil,oil filter and bypass oil filter,change the fuel filter,drain the oil from the fuel tank when necessary,and tension the V-belt.
    8.Check whether the core of the radiator and air-cooled intercooler is blocked and needs to be cleaned.Check whether the air pipe and its hose joint are free of broken parts and new ones.Tighten the clamp.Check whether there is no leakage at the oil inlet and return of the booster.
    9.Every 1200 hours,ask professional personnel to check and adjust the valve clearance.Before the check and adjustment,the engine should be stopped and cold.Every 2400 hours,ask professional personnel to disassemble and check and adjust the fuel injector.The professional personnel should check the working condition of the supercharger,and carry out routine inspection on the engine and generator parts.Every 6 months,replace the coolant filter,every year Clean the cooler and change the coolant.

     

    Installation instructions for diesel generator set

    1.Foundation
    The installation of the unit shall consider the floor load,the location of the passage and maintenance,vibration,ventilation,the connection and heat insulation of the exhaust pipe,the size and location of the fuel tank,and shall be subject to the local or national environmental protection regulations.
    The unit has excellent shock absorption performance,so the generator unit does not need a specific foundation,the unit can be directly installed
    On level and concrete floor with sufficient strength.The ground is required to be level and flat,and the flatness is required to be within±0.5°plane,and the ground must be able to bear 1.5~2 times of the static weight of the generator unit itself.
    The concrete installation base is a reliable installation method.The base is usually 100~200 higher than the ground.The calculation formula of its thickness d is as follows:
    D=W/(d×B×L)
    Where w=total mass of generator set(kg)
    D=specific gravity of concrete,grade 450,usually 2300(kg/m3)
    B=width of concrete base(m)
    L=length of concrete base(m)
    The volume ratio of concrete(cement,sand,stone)is 1:2:4 or 1:3:5 or 1:3:6
    2.Computer room
    There must be enough space in the machine room to make the air circulate freely,which is very important for ensuring the normal performance of the unit,reducing the power loss of the unit and ensuring the normal service life of the unit.
    There should be no other inflammable and explosive articles or objects that are easy to be drawn into the protective net cover of the unit,or even directly inhaled into the unit and may affect the normal use of the unit.In order to prevent the return of hot air,an air guide cover is set between the cooling water tank and the exhaust outlet of the unit to prevent the hot air from circulating indoors.
    For the installation and construction of the unit without special requirements,the design requirements of the machine room are not high.Only on the premise of ensuring that the exhaust back pressure does not exceed the specified value,the air inlet and outlet of the machine room can meet the requirements of the technical specifications,and the heating backflow can be avoided,and enough operation and maintenance space can be reserved inside the machine room.
    The engine room must ensure the air intake volume to supplement the air consumed for engine combustion and discharge a large amount of heat emitted by the unit during operation out of the machine room through the radiator core,so as to make the temperature in the machine room as close as possible to the ambient temperature and keep the body temperature in the normal working range.
    It should be ensured that the minimum net area of the exhaust outlet is not less than 1.25 times of the effective area of the radiator core,the center position of the exhaust outlet should be consistent with the center position of the radiator core of the unit as far as possible,and the width height ratio of the exhaust outlet should be the same as that of the radiator core as far as possible.

    Yangzhou Kangcheng power generation equipment Co.,Ltd.is mainly engaged in the R&D and production of general steam,diesel and gas generator sets.It is to manufacture open shelf diesel generator set,low noise diesel generator set,fully automatic diesel generator set,4-wheel,3-wheel and 2-wheel mobile power station diesel generator set.The selected diesel engine brands are:Volvo,Cummins,Benz,Daewoo,Dalian DEUTZ,Shangchai,Weichai,Yuchai,Wudong,Xichai,etc.Generator brands:Yangzhou Kangcheng,Jiangsu Lingyu,Wuxi Stanford,Shanghai marathon,Guangzhou inger,lileisenma,Siemens,Audi,etc.With Kangcheng as the leading brand,our products are well matched,beautiful and excellent in performance!Accurate market and product positioning,as well as optimized cost performance,is the choice of many customers after careful consideration.It is widely used in various industries at home and abroad,such as factories,hotels,real estate,buildings,railways,petroleum,mines,telecommunication systems,etc.The self-developed diesel generator set has advanced four protection,self starting and self switching,computer remote monitoring and other functions,and the power covers 3kw-2600kw.Each power section can provide standard unit,silent unit,on-board and trailer unit and parallel cabinet,and can realize fixed,mobile,automation,low noise,multi machine parallel,emergency power vehicle and other power supply schemes.At the same time,it can provide customers with related services such as unit capacity selection,machine room design,technical installation guidance and commissioning.

    Contact us

    Company name:Yangzhou Kangcheng power generation equipment Co.,Ltd
    Address:No.168,shuangxu Road,Jiangdu District,Yangzhou City,Jiangsu Province
    Direct sales hotline:138 1315 3554 176 0514 5977
    website:http://en.kcfdpower.com
     

     


    Yangzhou Kangcheng power generation equipment Co., Ltd

    24-Hour Hour Hotline

    138 1315 3554

    Record:苏ICP备18012807号

    Copyright:Yangzhou Kangcheng power generation equipment Co., Ltd

    [Website map]

    Unit configuration

    Pure copper brushless generator

    Zhongzhi intelligent controller

    ATS automatic switch cabinet

    Rain cover of generator set

    Generator set static sound box

    Generator set mobile power supply vehicle

    Contact us

    contact information